Daily Cleaning
Allow hob to cool completely
Wipe glass top with mild liquid detergent
Clean burner caps and rings with a soft brush
Remove food spills immediately to avoid stains
Weekly Cleaning
Remove burners and wash with warm soapy water
Clean burner holes using a pin (do not enlarge holes)
Wipe cast iron pan supports and dry thoroughly
Clean knobs with a damp cloth (do not use chemicals)
Deep Cleaning (Monthly)
Inspect burner cups for blockages
Clean vertical injectors gently
Check pan support rubber stoppers
Ensure ignition points are dry and free from grease
Do Not Use
Acidic cleaners
Steel wool / abrasive pads
Excessive water on burners
Harsh chemicals on glass top
Related Articles
ELICA FLEXI 470 LOTUS IND HD BRASS (4B, 70 CM) - Article
1. Overview The Elica Flexi 470 Lotus IND HD Brass is a premium 70 cm 4‑burner hob designed for modern modular kitchens. It features heavy‑duty brass burners, auto ignition, cast‑iron pan supports, and a durable toughened‑glass surface. Ideal for ...
Elica Hob IND FLEXI AB 470 DX DFS - 1. Overview
⭐ Desk Article 1: Product Overview – IND FLEXI AB 470 DX DFS Product Summary The IND FLEXI AB 470 DX DFS is a 4‑burner Flexi Hob‑Top designed for Indian cooking. It features brass heavy‑duty multi‑flame burners, auto ignition, sealed burner cups, and ...
Elica Hob IND FLEXI AB 470 DX DFS - 9. FAQs
⭐ Article 9: Customer FAQs – IND FLEXI AB 470 DX DFS 1. Does this hob have auto ignition? Yes, it has battery‑operated auto ignition. 2. What type of burners are used? Heavy‑duty brass multi‑flame burners for Indian cooking. 3. Can this be used as a ...
Elica Hob IND FLEXI AB 470 DX DFS - 5. Maintenance Guide
⭐ Desk Article 5: Maintenance Guide – IND FLEXI AB 470 DX DFS Daily Cleaning Wipe glass top with mild detergent Clean burner caps and rings Remove food spills immediately Weekly Maintenance Deep clean burner holes Check pan support stability Inspect ...
Elica Hob IND FLEXI AB 470 DX DFS - 2. Installation Guide
⭐ Desk Article 2: Installation Guide – IND FLEXI AB 470 DX DFS Pre‑Installation Requirements Ensure cut‑out size: 66 × 48 × 5 cm Gas line must be leak‑tested Use only ISI‑marked hose or copper pipe Keep electrical point accessible for auto ignition ...